What distinction does the networking reference establish?
Cisco's guide distinguishes hardware MAC addressing from IP addressing and explains that ARP maps an IP address to a corresponding MAC address in the described IPv4 context. A mapping between identifiers does not make them the same identifier.
Substation Drafting is independent and is not affiliated with Cisco. The dated guide provides the addressing distinction, not a current relay configuration procedure. Verify the selected IED, interface and network design against its actual approved documentation.
Sources: Cisco: Cisco IOS 15S: Address Resolution Protocol guide, updated 2 December 2012
Which fields should the drawing register separate?
Use controlled references to the authorized configuration record. Keep sensitive live network details inside the project's approved document-access boundary rather than include them in a public enquiry.
| Register field | Identity basis | Check |
|---|---|---|
| Equipment tag | Actual IED or network device | Does it match the asset record? |
| Physical interface | Port or approved interface reference | Which connection is being described? |
| MAC record | Actual applicable interface identifier | Was another port copied? |
| IP record | Approved configured address reference | Does it match the controlled plan? |
| Network context | Authorized segment or design reference | Is the intended context clear? |
| Revision | Configuration and drawing status | Were changes reconciled? |
How can a single address column conceal an error?
Illustrative example. A fictional relay has interfaces PORT-A and PORT-B. A drawing register contains one equipment row with an address copied from PORT-A, while its cable reference points to PORT-B. The sheet has an equipment tag and an address, but no traceable statement of which interface the value belongs to.
The reviewer separates the interface records and checks each against the authorized configuration. No real address is supplied here. The example does not assume that both ports use IP, that every port has a particular addressing arrangement, or that the recorded address can never change.
What closes a network drawing discrepancy?
Ask the designated protection and network owners to reconcile the actual port, addressing and configuration revision. Retain the original discrepancy and accepted update. Do not scan the production network, change an IED address or send test traffic merely to fill a document field.
Physical media, addressing, logical services and protection behavior need their own approved checks. This worksheet is not proof of connectivity, security or protection operation. Engineering sign-off is performed only by the registered engineer on the job.
Common questions
What else should the bid team know?
Can the equipment tag replace the interface reference?
No. A device can have more than one relevant interface.
Are MAC and IP the same address?
No. Record their actual different roles and mapping where applicable.
Does this worksheet authorize a network configuration change?
No. Use the designated engineering and network change process.