What does the Sepam example actually distinguish?

Schneider Electric's Sepam FAQ distinguishes residual current calculated from three phase-current measurements from residual current measured through the applicable input arrangement. Its Sum 3I and Input Io labels describe product-specific alternatives that depend on the actual sensor connections.

Substation Drafting is independent and is not affiliated with Schneider Electric. This is a document-reference review, not a wiring guide or instruction to select a setting. Use the approved manual and engineer-authorized configuration for the exact relay and sensors.

Sources: Schneider Electric: Schneider Electric FAQ FA86406: Sum 3I and Input Io, modified 15 June 2026

Which drawing references should remain separate?

Keep the function's displayed name, the physical input and the settings source in separate fields. A function label does not prove a dedicated sensor or establish a spare terminal's purpose.

Which drawing references should remain separate?
Reference fieldEvidenceQuestion for engineering
Relay identityExact model and manual revisionWhich functions are supported?
Quantity sourceCalculation or dedicated measurementWhere does this value originate?
SensorsApproved sensor arrangementDoes it match the documented function?
Physical inputAuthorised terminal reference if applicableIs a separate input actually used?
ConfigurationApproved settings packageDoes the selected source agree?
RevisionDrawing and settings dispositionWhich linked records need change?

How can one label conceal two evidence paths?

Illustrative example. A fictional register labels Function A as residual current and links it to three approved phase-current measurements. Function B carries the same display wording but links to a separately approved measurement input. A reviewer copies B's physical input reference into A's row solely because the names match.

The document check finds that the quantity source has been lost. The reviewer restores the distinct references and asks the engineer to resolve any actual inconsistency. The example does not establish which arrangement is suitable, what settings should be used or how any conductor should be connected.

What closes a source mismatch?

Obtain an authorized disposition that reconciles the actual equipment, sensor arrangement, settings and drawings. Retain superseded references so a later reviewer can follow the change. Do not invent an unused input to make a table complete.

No operation, test, protection-performance or installation approval follows from this worksheet. Engineering sign-off is performed only by the registered engineer on the job.

Common questions

What else should the bid team know?

Does a residual-current function always have a dedicated input?

No. Confirm its approved source and exact device documentation.

Can a setting label replace a terminal reference?

No. They identify different things.

Does this article tell a technician which setting to select?

No. Use the engineer-authorized configuration and safety process.

Primary sources

  1. Schneider Electric FAQ FA86406: Sum 3I and Input Io, modified 15 June 2026Schneider Electric